Cardiac troponin I and Cardiac Diseases

Troponin (Tn) is a regulatory protein related to myocardial and skeletal muscle contraction. It consists of three subunits: troponin I (TnI), troponin T (TnT) and troponin C (TnC). TnI can also be divided into three subtypes: skeletal muscle fast-response protein I (fsTnI), slow-reaction troponin I (ssTnI) and cardiac troponin I (cTnI).

Under normal circumstances, most cTnI combine with TnC to form a complex, and there are few free forms of cTnI in the cytoplasm. When the myocardium is complete, cTnI cannot enter the blood circulation through the cardiac membrane. Therefore, it is difficult to detect cTnI in plasma under normal conditions. When myocardial degeneration and necrosis occur due to ischemia and hypoxia, cTnI can enter the interstitium through the damaged myocardial membrane and then enter the blood vessels and lymphatic vessels. Plasma cTnI can be increased to 5-50 times of normal people within 3-12 hours of myocardial injury, which can last for a week or more. The plasma cTnI of patients with myocardial infarction began to increase at the early stage, and increased significantly after 4h, reaching the peak at 18h, averaging 112pg/L, and the abnormal increase lasted 6 to 8 days. The specificity of cTnI in diagnosing myocardial infarction is 96%, and its sensitivity is 97%, and it can effectively distinguish skeletal muscle from other tissue injuries, which is more sensitive and specific than lactate dehydrogenase, creatine kinase and other indicators.

Hypertensive myocardial hypertrophy is an autosomal dominant hereditary disease associated with ventricular hypertrophy and muscle fiber disorder, and is the most common cause of sudden death in young people. Kimura et al. systematically studied the submyogenes of 184 patients with cardiac hypertrophy, including cTnI, actin and cTnC, and found that many patients had mutations in cTnI genes. Family analysis also found that the 145th Arg mutation in cTnI protein was Gly, or the 206th Lys mutation was Gly, suggesting that cTnI mutation may be one of the causes of cardiac hypertrophy.

Chemtron biotech troponin i rapid test kit is of high quality. Learn more about the troponin i rapid test kit from chemtron biotech.
Related News
  • Application Of Chlamydia Test Reagent In Women

    Application Of Chlamydia Test Reagent In Women

    August 8, 2018Intended use:It is suitable for screening suspected chlamydia trachomatis infection by various medical institutions, and can qualitatively detect whether chlamydia trachomatis antigen is contained in ...view
  • Quantum Dot Immunochromatography

    Quantum Dot Immunochromatography

    August 8, 2018QDs(quantum dots) is a semiconductor fluorescent nanoparticle, usually between 1 and 20nm in diameter and is composed of ii-vi or iii-v elements. Compared with fluorescence labeling materials of organ...view
  • Application And Sample Requirements Of Ovulation Test Paper

    Application And Sample Requirements Of Ovulation Test Paper

    August 8, 2018Intended useThis reagent was used to qualitatively detect the changes of luteinizing hormone in women's urine in vitro, so as to determine the "safe period" of ovulation time and women's menstrual cyc...view
  • Precautions For Chlamydia Detection

    Precautions For Chlamydia Detection

    August 8, 20181. Diagnosis outside the donor and use by professionals only.2. Do not use after expiration: do not mix different batches of reagents or test kits for use;3. Do not mix the lid of solution A and solut...view
  • Announcements of One Step 10miu Pregnancy Test

    Announcements of One Step 10miu Pregnancy Test

    August 8, 20181. Pay attention to the production date on the packaging box, and do not use expired test CARDS, because chemical agents will be ineffective if they take too long.2. In order to reduce the probability...view
  • Rapid Kit For HCV Nucleic Acid Detection And Its Detection Method 2

    Rapid Kit For HCV Nucleic Acid Detection And Its Detection Method 2

    July 26, 20185. According to the rapid detection method of hepatitis c virus (HCV) nucleic acid in the kit described in claim 1, its characteristics are: The primer is the nucleotide sequence shown in SEQ ID no. 1...view
  • TEL:+86-21-68129666
  • FAX:+86-21-68129222
  • EMAIL:international@chemtronbio.com
  • ADDRESS:No.518, Qingdai Rd., International Medical Park, Pudong, 201318, Shanghai, P.R.China