Shanghai Chemtron Biotech Co.Ltd.

cTnI quantitative rapid test-Cardiac Troponin I Diagnostic Kit

Specimen: Serum/Plasma
Specimen volume: 80μl
Detection range: 1-50ng/ml
Reference value:
  • Product Description
Product Profile of cTnI quantitative rapid test-Cardiac Troponin I Diagnostic Kit
Chemtrue® cTnI Diagnostic Kit adopts the technology of colloidal gold chromatographic immunoassay and principle of double-antibody sandwich to detect the level of cTnI in serum and plasma specimens. Combined with ECG and clinical symptoms, it can be used in clinical early diagnosis of AMI, UAP, acute myocarditis and ACS.

Product Property of cTnI quantitative rapid test-Cardiac Troponin I Diagnostic Kit
Specimen: Serum/Plasma
Specimen volume: 80μl
Detection range: 1-50ng/ml
Reference value: <1ng/ml
Precision: CV<15%
Accuracy: Relative deviation <20%
Interpretation time: 15min
Test time: 15s

Product Advantages of cTnI quantitative rapid test-Cardiac Troponin I Diagnostic Kit
A preferred index of AMI diagnosis;
One-step rapid testing, and effectively reduce TAT to give patients timely therapy;
Strong ability to anti-interference;
Advanced testing method of double-antibody sandwich.

Clinical Applications of cTnI quantitative rapid test-Cardiac Troponin I Diagnostic Kit
Clinical diagnosis, prognosis evaluation and risk stratification of Acute Coronary Syndrome;
To measure the area of MI;
To monitor myocardial damage caused by cardiac operation;
To evaluate the effect of thrombolytic therapy;
To detect that cardiac dissolution in non-ischemic heart failure;
A new marker for left-ventricular hypertrophy in primary hypertension.

Leave us Message

Related Products
  • AMI Quantitative Rapid Test(CTNI/CK-MB/MYO test)

    AMI Quantitative Rapid Test(CTNI/CK-MB/MYO test)

    December 28, 2017Specimen: Whole blood/Serum/Plasma
    Specimen volume: 80μl-100μl
    Detection range: CTnI (1ng/ml-50ng/ml); MYO (25ng/ml-500ng/ml); CK-MB (5ng/ml-100ng/ml)
    Precision: CV≤15%
    Accuracy: Relative deviation
    view
  • 6 Panel Drug Test

    6 Panel Drug Test

    December 28, 2017Chemtrue® One-Step DOA Test is a lateral flow, one-step immunoassay for qualitative detection of drugs and their metabolites in human urine at a cut-off concentration.view
  • Microalbuminuria Rapid Test-MAU Rapid Test

    Microalbuminuria Rapid Test-MAU Rapid Test

    December 28, 2017Test results: 5 minutes
    Cut-off: 15-20μg/ml
    Specimen: Urine
    Long shelf life: 24 months at room temperature
    view
  • TEL:+86-21-68129666
  • FAX:+86-21-68129222
  • EMAIL:international@chemtronbio.com
  • ADDRESS:No.518, Qingdai Rd., International Medical Park, Pudong, 201318, Shanghai, P.R.China